Set Time Profile Entry Properties
Using the time profile entry properties dialog, you can define the general settings, such as the name and the value shown for the time profile.
General
Name - Enter a name for the time profile entry. This name is shown as a legend on the value table.
Profile - Select a time profile from the list.
Value - You can show the following values of a time profile as a graphic:
Value 1 - Value 9 - Free values on a time point.
Display graphic - The display of the values as a line is hidden and shown. The value is however still shown in the value table.
Display value tables - The value is hidden or shown within the value table.
Display axis coordinates - The time point is additionally hidden or shown within the value table.
Display support lines - A help line is drawn from the value table to the value point.
Graphic attributes
Line width - The width of the line. The value is shown in points (pkt), (1 inch equals 72
Line color - The color of the line.
Style - A selection list for the line style.
Points width - Should the data point be emphasized, enter a value that is larger than the line width.
Fill area below line - For the display of the values, the area underneath the line is filled with the selected background color / pattern.
Background color - The color for the background and the fill beneath the line.
Pattern - The pattern for the display under the line.
Fill between other lines - Only 2 lines can have this option set. Those having this option set,have the area between the 2 lines filled. If checked, the Fill below line gets disabled.
Smooth curve - Should the time profile have relatively few time points with values, the curve can be smoothed using this option.
Factor - The standard value is 6,5.